High-Security Data Center

EasySpeedy » Knowledge Base » Security » High-Security Data Center

Data Center

All hardware, infrastructure, network and customer servers are solely our property. Everything has been purchased by ourselves and has been paid for in cash. We do not believe in leasing.

Making business with us you are dealing with us directly. You are NOT dealing with a reseller.

Our top secure Data Center is located in Copenhagen, Denmark. Our building is designed to provide redundant facilities to Telecoms, ISPs, and hosting providers like ourselves.

Redundant Power

Our entire data center is supplied with dual power feeds, and have massive battery backups.

230V AC and 400V AC, UPS, -48V DC with battery backup, and ground/earth system provides continuous power. Also our data center has redundant diesel backup generators (N+1).

Each rack of servers is supplied with multiple power sources connected to redundant source transfer switches, this means there is always two active power sources to each server.

Power cabling is laid under the raised anti-static computer flooring. Data cabling is usually in trays overhead, but can be laid beneath the flooring. We provide a structured cabling service and supervise our engineer's work in order to guarantee quality and flexibility.

Diesel Generator Specifications

2 x 65,300ccm (16 cyl. each) pre-heated diesel power generators deliver 1,383 KVA each at 1,500 rpm.

Diesel tank capacity is 130,000 liters. Fuel consumption is 385 liters/hour per generator. One tank of diesel will be sufficient for running the entire data center for one week with both generators.

Physical Security

Your server is physically well protected. This is what we do to ensure that no one can get near your server unless authorized by us.

  • Only our authorized staff are allowed on-site
  • Security zones using designated alarm and card-key access
  • Logging of all entries
  • Video monitoring of all facilities

Advanced Fire Protection

Sensitive detection and suppression systems is our first line of defense against fire.

  • Fire-retardant walls and flooring
  • Gas-based fire suppression systems (Inergen)
  • Hand-held CO2 fire extinguishing systems

Climate and Environmental Control

Hardware performance and reliability are closely tied to climate conditions.

We guarantee the following climatic conditions:

  • Average temperature: 18°C - 25°C
  • Humidity: 40% - 60%
  • Redundant air-conditioning
http://easyspeedy.com/knowledge-base/security/high-security-data-center
http://easyspeedy.com/knowledge-base/security/high-security-data-center

News

News Archive

Leaving Customers Say...

Dear Easyspeedy,

First of all we have absolutely no objections to your service. Our reason for cancellation is that our organization is undertaking a generation-shift.

Sonokids is working with blind children and some of them has now grown adult and set up there own servers in The Netherlands.

We would especially like to thank Tina and Lisa very much for being so patient about payment when we had hard times 6-7 years ago.

We will keep recommending Easyspeedy throughout our network.

Kind regards

John Norgaard and Phia Damsma